Vertical Contact Probe Cards are developed for multi-die probing with matrix configuration, high temperature probing (up to 150°C), C4 (array bumps) configuration, and high speed memory testing such as Rambus and SDRAM.
|
| |
|
|
|
VCPC Scrub Mark | Cantilever Scrub Mark | |
Alignment Accuarcy: | ±10µm (±15µm at 125°C) |
Planarity: | ±10µm (±15µm at 125°C) |
Minimum Pitch: | 118µm center to center, |
Spacing Limit: | 4 adjacent dies cannot be at pitch |
Probe Material: | Tungsten, Rhenium Tungsten, NT2 (new Tungsten), |
Probe Tip Lenght: | 400µm to 450µm |
Probe Tip Diameter: | 20µm to 30µm (radius tip) |
Maximum Device Size: | 120mm x 120mm |
Contact Resistance: | 1 max (O.D.=70µm, I=10mA, Al pad) |
Contact Force: | 15g @ 50µm overdrive (ReW) |
Maximum Current: | 250mA dry switch |
Temperature Range: | -43°C to 150°C |
Lifecycle: | 1 million touchdowns |
VCPC Series:
VCPC 1
| VCPC 2
|
VCPC 2 N
| |
The new HT- 6000/7000 Series Cleaning Sheet is recommended for on-line & off-line VCPC cleaning.