+49 89 4411900   |   aus Freude am Support. — we love to support you — au plaisir de vous assister

High-performance Peltier Modules

uwe electronic’s 70-series has been specifically designed for cycling applications. Tests show TEM life time is significantly greater than a standard module under the same thermal cycling conditions. Typical application areas include instrumentation, chillers, PCR cyclers and analyzers. These TEMs are also available with different configurations.


Peltier Cyclermodule

 

designationI max (A)U max (V)Qc max (W)Δt max (°C)T max °C)width1 (mm)length1 (mm)height (mm)Sealing
without / Silicon / Epoxy
UEPT-515-031-040D2004,04,09,07817015,015,03,2
 / 
 / 
UEPT-530-127-060D2006,018,056,07817029,029,03,5
 / 
 / 
UEPT-540-127-040D2004,018,038,07817039,039,03,8
 / 
 / 
UEPT-540-127-085D2008,018,079,07817039,039,03,3
 / 
 / 
UEPT-540-127-110D20011,018,0104,07817039,039,03,5
 / 
 / 
UEPT-555-241-060D2006,034,0114,07817055,055,03,5
 / 
 / 
UEPT-555-242-160D20016,034,0289,07817055,055,03,5
 / 
 / 
UEPT-5RE-023-030D2003,03,05,0781707,022,02,9
 / 
 / 

 

Peltier Hot Side / Cold Side
Type 2 (T2) TEMs feature a "porch" for more accurate heat distribution.
This makes the L2 dimensions slightly longer than the L1 dimension.

Imax: Maximum input current in amperes at Qc=0 and ΔTmax
Vmax: Maximum DC input voltage in volts at Qc=0 and ΔTmax
ΔTmax: Maximum temperature differential in °C at Qc=0 and Imax
Qcmax: Maximum heat pumping capacity in watts at Imax and ΔT=0
T hot: Temperature of TEM hot side during operation